Skip to main content
Limitless Lisa homeLimitless Lisa

The lab side

Tech & Research

The work happening behind the interviews — original research, and the tools we’re building with partners to make daily life easier for people living with ALS.

Original research

Research

Ongoing scientific work led alongside Dr. Farooque focused on the earliest possible detection and closest possible monitoring of ALS.

In progress

Continuous Passive Digital Phenotyping for Early Detection and Longitudinal Monitoring of Limb-Onset ALS

Background Amyotrophic Lateral Sclerosis (ALS) is a progressive neurodegenerative disease in which early diagnosis remains difficult because clinical evaluation typically occurs only after noticeable functional decline. Emerging disease-modifying therapies further emphasize the importance of identifying subtle behavioral changes before substantial motor neuron loss occurs given these drugs are most effective early in ALS decline. Existing passive digital phenotyping research has demonstrated that individual behavioral modalities, including smartphone keystroke dynamics for fine-motor assessment and passive mobility sensing for gross-motor behavior, can independently capture clinically relevant changes. However, these modalities have largely been investigated in isolation and rely on static population thresholds rather than individualized longitudinal monitoring. Objective This work proposes a computational framework for early neuromuscular anomaly detection that continuously monitors passive smartphone-derived behavioral signals over time. Rather than attempting to diagnose ALS directly, the framework identifies sustained behavioral deviations from an individual's personalized baseline that may warrant earlier clinical evaluation. Novel Contribution The primary contribution of this work is not the introduction of new physiological biomarkers, but the development of a unified computational architecture that integrates multiple independently validated passive digital phenotyping modalities into a single longitudinal monitoring system. Specifically, this framework introduces: Pre-Symptomatic At-Risk Cohort Targeting vs. Post-Symptomatic Tracking: Prior literature almost exclusively evaluates digital biomarkers on patients who have already received an ALS diagnosis or present obvious clinical symptoms. This framework shifts the deployment baseline to at-risk populations (such as genetic carriers or individuals with familial history) before visible motor signs emerge, serving as a true early screening system. Multimodal Fusion for Cross-Modality Synergy: Instead of treating fine-motor kinetics (typing habits) and gross-motor mobility (activity patterns) as isolated streams, the architecture initially implements a gated mechanism to detect early deviations in either domain, subsequently leveraging transfer learning to map how these data sources interact. This allows the framework to isolate subtle, concurrent relationships across distinct motor systems that individual data streams would miss, yielding a unified behavioral indicator that outperforms single-modality models. Idiographic Personalized Baselines vs. Nomothetic Thresholds: Instead of evaluating user telemetry against rigid, population-wide averages (asking "Does this person look like an average ALS patient?"), the model establishes an individualized calibration engine. The system asks "Has this specific person's behavior changed from what is normal for them?", accommodating high baseline behavioral diversity. Continuous Longitudinal Synthesis: The dual-branch design processes observations through sequential sliding windows, enabling the framework to identify subtle, compounding trends across weeks and months that would remain invisible to single-snapshot clinical evaluations. Proactive Screening Focus over Autonomous Diagnosis: Recognizing the legal and clinical boundaries of digital medicine, the architecture is explicitly designed as a passive screening aid to accelerate clinical referrals and generate objective longitudinal motor-behavior data that clinicians can use to support earlier evaluation and potentially accelerate the diagnostic process rather than an autonomous diagnostic classifier. Zero-Burden Passive Monitoring: The pipeline runs entirely in the background of consumer smartphone hardware without requiring active clinical visits or structured interaction tasks, minimizing patient burden and maximizing long-term data adherence. To evaluate the computational framework before clinical deployment, the system is trained and evaluated using literature-informed synthetic datasets constructed from previously validated behavioral findings reported in ALS and passive sensing research. This allows systematic evaluation of the proposed architecture while avoiding unsupported clinical claims prior to prospective validation.

Assistive technology

Tech collaborations

Building alongside Bridging Voice, ElevenLabs, and other partners to expand what AAC and communication tools can do.

Nothing yet published

Voice Humanization — The Expressive Eye-Gaze AAC Soundboard Grid

Traditional speech devices sound static and monotone. This customizable, eye-gaze-compatible soundboard application natively integrates ElevenLabs’ expressive audio rendering. The grid layout includes dedicated, large-target toggle keys for context and emotional parameters (such as [laughs], [sighs], or shifting to a whispering tone). It dynamically appends these formatting parameters to the text payload sent to the API, allowing a non-verbal user to inject immediate human nuance into real-time conversations.